Skip to content
electrolite®empower your world

For Panel builders, plant maintenance teams and process industry

Industry & panel builders

Vadodara is a manufacturing city, and industrial distribution carries real weight here. What a plant or a panel builder needs from a supplier is rarely the lowest price on a single line item; it is the confidence that the devices will coordinate, that the drawing will match what arrives, and that a replacement can be found the same day when a line is down.

We hold the full Hager range from a 6 A miniature breaker to a 4000 A air circuit breaker, alongside Siemens protection and the SINOPLUS value line - so a panel can be built from one brand where the specification demands it, or value-engineered across two where it does not.

Discrimination is where specifications quietly fail

If a downstream fault trips the incomer instead of the local breaker, the whole plant stops for a fault in one machine. Getting that right means matching curves, breaking capacities and time delays across three or four levels of the distribution - which is a design exercise, not a purchasing one. It is also why buying each level from whoever is cheapest tends to produce an installation that works until the first real fault.

What we supply for this

Incoming protection

Hager hws air circuit breakers, 630 A to 4000 A, at 50, 66 and 85 kA, in fixed and draw-out versions. Type L trip units for standard duty, Type A adding current measurement on an LCD, Type H adding communications for plants running energy monitoring.

Distribution and motor circuits

Hager h3+ MCCBs from 40 A to 630 A with adjustable LSI and LSIG trip units, HWC contactors from 9 A to 630 A, and HWR overload relays. Siemens 5SL7 K-curve breakers for motor circuits that would nuisance-trip a C curve on inrush.

Changeover and supply continuity

Manual changeover switches from 63 A to 800 A, motorised automatic transfer switches with controller, and automatic changeover current limiters for sites running on generator backup.

Control panel build

RR Kabel control cable in 5 to 24 cores, screened and pair-screened instrumentation cable to BS EN 50288-7, and Precision FRLS panel trunking in standard and thin slot.

Cable routing, earthing and surge protection

OBO Bettermann cable trays, welded cable ladders and mesh trays in hot-dip galvanised and stainless steel, with published loads for every support spacing. OMEX earth rods and equipotential busbars for the earthing system, and the LightningController Type 1+2 arrester for the main panel.

Guides

Send us the drawing or the schedule and we will specify it.

We will tell you what the specification needs, where it can safely be value-engineered, and where it should not be.